Generators
-
17 kVA Cummins C22D5 1ph Silent Diesel Generator
Standby: 17 kVA / 17 kW Voltage: 240V Prime: 15.5 kVA / 15.5 kW Frequency: 50Hz Engine: Cummins X2.5-G2 Amps Per Phase: 63.7 Alternator: Stamford S0L2-M1 Control Panel: PS0600 -
22 kVA Cummins C28D5 1ph Silent Diesel Generator
Standby: 22 kVA / 22 kW Voltage: 240V Prime: 20 kVA / 20 kW Frequency: 50Hz Engine: Cummins X2.5-G2 Amps Per Phase: 79.7 Alternator: Stamford S0L2-P1 Control Panel: PS0600 -
28 kVA Cummins C33D5 1ph Silent Diesel Generator
Standby: 28.3 kVA / 28.3 kW Voltage: 240V Prime: 25.7 kVA / 25.7 kW Frequency: 50Hz Engine: Cummins X3.3-G1 Amps Per Phase: 95.6 Alternator: Stamford S0L2-P1 Control Panel: 1.1 -
30 kVA Cummins C38D5 1ph Silent Diesel Generator
Standby: 30 kVA / 30 kW Voltage: 240V Prime: 27 kVA / 27 kW Frequency: 50Hz Engine: Cummins X3.3-G1 Amps Per Phase: 110.1 Alternator: Stamford S1L2-J1 Control Panel: 1.1 -
22 kVA Cummins C22D5Q Silent Diesel Generator
Standby: 22 kVA / 18 kW Voltage: 400V Prime: 20 kVA / 16 kW Frequency: 50Hz Engine: Cummins X2.5-G2 Amps Per Phase: 31.8 Alternator: Stamford S0L2-G1 Control Panel: PS0600 -
33 kVA Cummins C33D5Q Silent Diesel Generator
Standby: 33 kVA / 26 kW Voltage: 400V Prime: 30 kVA / 24 kW Frequency: 50Hz Engine: Cummins X3.3-G1 Amps Per Phase: 47.6 Alternator: Stamford S0L2-M1 Control Panel: PS0600 -
28 kVA Cummins C28D5 Silent Diesel Generator
Standby: 27.5 kVA / 22 kW Voltage: 380-415V Prime: 25 kVA / 19.8 kW Frequency: 50Hz Engine: Cummins X2.5-G2 Amps Per Phase: 39.6 Alternator: Stamford S0L2-P1 Control Panel: PS0600 -
38 kVA Cummins C38D5Q Silent Diesel Generator
Standby: 38 kVA / 30.4 kW Voltage: 400V Prime: 35 kVA / 28 kW Frequency: 50Hz Engine: Cummins X3.3-G1 Amps Per Phase: 54.8 Alternator: Stamford S1L2-J1 Control Panel: PS0600 -
28 kVA Cummins C28D5Q Silent Diesel Generator
Standby: 27.5 kVA / 22 kW Voltage: 400V Prime: 25 kVA / 20 kW Frequency: 50Hz Engine: Cummins X2.5-G2 Amps Per Phase: 39.7 Alternator: Stamford S0L2-M1 Control Panel: PS0600 -
44 kVA Cummins C44D5EQ Silent Diesel Generator
Standby: 44 kVA / 35 kW Voltage: 400V Prime: 40 kVA / 32 kW Frequency: 50Hz Engine: Cummins 4BTAA3.3-G14 (Stage IIIa) Amps Per Phase: 63.6 Alternator: Stamford UC224C Control Panel: PS0600 -
55 kVA Cummins C55D5EQ Silent Diesel Generator
Standby: 55 kVA / 44 kW Voltage: 400V Prime: 50 kVA / 40 kW Frequency: 50Hz Engine: Cummins 4BTAA3.3-G14 (Stage IIIa) Amps Per Phase: 79.5 Alternator: Stamford UC224D Control Panel: PS0600 -
66 kVA Cummins C66D5EQ Silent Diesel Generator
Standby: 66 kVA / 53 kW Voltage: 400V Prime: 60 kVA / 48 kW Frequency: 50Hz Engine: Cummins 4BTAA3.3-G14 (Stage IIIa) Amps Per Phase: 95.4 Alternator: Stamford UC224F Control Panel: PS0600