Standby Generators
-
55 kVA Cummins C55D5EQ Silent Diesel Generator
Standby: 55 kVA / 44 kW Voltage: 400V Prime: 50 kVA / 40 kW Frequency: 50Hz Engine: Cummins 4BTAA3.3-G14 (Stage IIIa) Amps Per Phase: 79.5 Alternator: Stamford UC224D Control Panel: PS0600 -
66 kVA Cummins C66D5EQ Silent Diesel Generator
Standby: 66 kVA / 53 kW Voltage: 400V Prime: 60 kVA / 48 kW Frequency: 50Hz Engine: Cummins 4BTAA3.3-G14 (Stage IIIa) Amps Per Phase: 95.4 Alternator: Stamford UC224F Control Panel: PS0600 -
90 kVA Cummins C90D5 Silent Diesel Generator
Standby: 90 kVA / 72 kW Voltage: 380-415V Prime: 82 kVA / 66 kW Frequency: 50Hz Engine: Cummins 6BTA5.9-G5 Amps Per Phase: 129.6 Alternator: Stamford UCI224G Control Panel: 1.2 -
110 kVA Cummins C110D5 Silent Diesel Generator
Standby: 110 kVA / 88 kW Voltage: 380-415V Prime: 100 kVA / 80 kW Frequency: 50Hz Engine: Cummins 6BTA5.9-G5 Amps Per Phase: 159 Alternator: Stamford UCI274C Control Panel: 1.2 -
150 kVA Cummins C150D5 Silent Diesel Generator
Standby: 150 kVA / 120 kW Voltage: 380-415V Prime: 136 kVA / 109 kW Frequency: 50Hz Engine: Cummins 6BTAA5.9-G6 Amps Per Phase: 217 Alternator: Stamford UCI274E Control Panel: 1.2 -
170 kVA Cummins C170D5 Silent Diesel Generator
Standby: 170 kVA / 136 kW Voltage: 380-415V Prime: 155 kVA / 124 kW Frequency: 50Hz Engine: Cummins 6BTAA5.9-G7 Amps Per Phase: 245 Alternator: Stamford UCI274F Control Panel: 1.2 -
220 kVA Cummins C220D5E Silent Diesel Generator
Standby: 220 kVA / 176 kW Voltage: 380-415V Prime: 200kVA / 160 kW Frequency: 50Hz Engine: Cummins QSB7-G5 (Stage IIIa) Amps Per Phase: 318 Alternator: Stamford UCI274H Control Panel: 1.2 -
200 kVA Cummins C200D5E Silent Diesel Generator
Standby: 200 kVA / 160 kW Voltage: 380-415V Prime: 182 kVA / 146 kW Frequency: 50Hz Engine: Cummins QSB7-G5 (Stage IIIa) Amps Per Phase: 289 Alternator: Stamford UCI274H Control Panel: 1.2 -
330 kVA Cummins C330D5 Silent Diesel Generator
Standby: 330 kVA / 264 kW Voltage: 380-415V Prime: 300 kVA / 240 kW Frequency: 50Hz Engine: Cummins QSL9-G5 Amps Per Phase: 475.2 Alternator: Stamford HC4D Control Panel: 1.2 -
275 kVA Cummins C275D5 Silent Diesel Generator
Standby: 275 kVA / 220 kW Voltage: 380-415V Prime: 250 kVA / 200 kW Frequency: 50Hz Engine: Cummins QSL9-G5 Amps Per Phase: 396 Alternator: Stamford UCD274K Control Panel: 1.2 -
300 kVA Cummins C300D5 Silent Diesel Generator
Standby: 300 kVA / 240 kW Voltage: 380-440V Prime: 275 kVA / 220 kW Frequency: 50Hz Engine: Cummins QSL9-G5 Amps Per Phase: 432 Alternator: Stamford HC4D Control Panel: 1.2 -
1100 kVA Cummins C1100D5B Open Diesel Generator
Standby: 1132 kVA / 906 kW Voltage: 380-440V Prime: 1029 kVA / 823 kW Frequency: 50Hz Engine: Cummins QST30-G4 Amps Per Phase: 1630 Alternator: Cummins KTA38-G14 Control Panel: 3.3