Standby Generators
-
33 kVA Cummins C33D5Q Silent Diesel Generator
Standby: 33 kVA / 26 kW Voltage: 400V Prime: 30 kVA / 24 kW Frequency: 50Hz Engine: Cummins X3.3-G1 Amps Per Phase: 47.6 Alternator: Stamford S0L2-M1 Control Panel: PS0600 -
28 kVA Cummins C28D5 Silent Diesel Generator
Standby: 27.5 kVA / 22 kW Voltage: 380-415V Prime: 25 kVA / 19.8 kW Frequency: 50Hz Engine: Cummins X2.5-G2 Amps Per Phase: 39.6 Alternator: Stamford S0L2-P1 Control Panel: PS0600 -
38 kVA Cummins C38D5Q Silent Diesel Generator
Standby: 38 kVA / 30.4 kW Voltage: 400V Prime: 35 kVA / 28 kW Frequency: 50Hz Engine: Cummins X3.3-G1 Amps Per Phase: 54.8 Alternator: Stamford S1L2-J1 Control Panel: PS0600 -
28 kVA Cummins C28D5Q Silent Diesel Generator
Standby: 27.5 kVA / 22 kW Voltage: 400V Prime: 25 kVA / 20 kW Frequency: 50Hz Engine: Cummins X2.5-G2 Amps Per Phase: 39.7 Alternator: Stamford S0L2-M1 Control Panel: PS0600 -
44 kVA Cummins C44D5EQ Silent Diesel Generator
Standby: 44 kVA / 35 kW Voltage: 400V Prime: 40 kVA / 32 kW Frequency: 50Hz Engine: Cummins 4BTAA3.3-G14 (Stage IIIa) Amps Per Phase: 63.6 Alternator: Stamford UC224C Control Panel: PS0600 -
500 kVA Cummins C500D5 Silent Diesel Generator
Standby: 500 kVA / 400 kW Voltage: 380-440V Prime: 455 kVA / 364 kW Frequency: 50Hz Engine: Cummins QSZ13-G5 Amps Per Phase: 720 Alternator: Stamford HC5D Control Panel: 2.2 -
550 kVA Cummins C550D5 Silent Diesel Generator
Standby: 550 kVA / 440 kW Voltage: 380-440V Prime: 500 kVA / 400 kW Frequency: 50Hz Engine: Cummins QSZ13-G10 Amps Per Phase: 792 Alternator: Stamford S5E Control Panel: 2.2 -
700 kVA Cummins C700D5 Open Diesel Generator
Standby: 706 kVA / 565 kW Voltage: 380-440V Prime: 640 kVA / 512 kW Frequency: 50Hz Engine: Cummins VTA28-G5 Amps Per Phase: 1016 Alternator: Stamford HC5F Control Panel: 3.3 -
825 kVA Cummins C825D5A Open Diesel Generator
Standby: 825 kVA / 660 kW Voltage: 380-440V Prime: 750 kVA / 600 kW Frequency: 50Hz Engine: Cummins VTA28-G6 Amps Per Phase: 1188 Alternator: Stamford S6L1D-C4 Control Panel: 3.3 -
825 kVA Cummins C825D5 Silent Diesel Generator
Standby: 825 kVA / 660 kW Voltage: 380-440V Prime: 750 kVA / 600 kW Frequency: 50Hz Engine: Cummins QSK23-G3 Amps Per Phase: 1188 Alternator: Stamford HC6G Control Panel: 3.3 -
900 kVA Cummins C900D5 Open Diesel Generator
Standby: 900 kVA / 720 kW Voltage: 380-440V Prime: 820 kVA / 656 kW Frequency: 50Hz Engine: Cummins QSK23-G3 Amps Per Phase: 1181 Alternator: Stamford S6L1D-D4 Control Panel: 3.3